einstein (São Paulo). 31/Jan/2014;11(4):467-71.
Adequacy of oxygenation parameters in elderly patients undergoing mechanical ventilation
DOI: 10.1590/S1679-45082013000400011
OBJECTIVE: To compare ideal PaO2 with PaO2 found, ideal PaO2/FiO2 of room air with the one found, and ideal FiO2 with FiO2 found in mechanically ventilated elderly patients. METHODS: Cross-sectional study that evaluated elderly mechanically ventilated patients for at least 72 hours and who underwent three subsequent blood gas analyses. RESULTS: The sample consisted of 48 elderly with mean age of 74.77±9.36 years. There was a significant difference between the ideal PaO2 and the one found (p<0.001), between FiO2 corrected and the offered one, and also between ideal PaO2/FiO2 of room air and the PaO2/FiO2 found (p<0,001). CONCLUSION: A significant increase was seen in PaO2 and FiO2 and in alterations of gas exchange by PaO2/FiO2 index than those found in normal parameters.