OBJECTIVE: To establish a routine for the extraction of the total levels of CoQ10 in human plasma through the Ultra High Performance Liquid Chromatography (UHPLC). METHODS: Two extraction protocols were tested: a) methanol: hexane and b) 1-propanol. The following parameters were analyzed: extraction temperature (19ºC and 4ºC), extraction tubes (glass and polypropylene), and surfactants (SDS, Triton X-100, Tween-20) at different concentrations, i.e., 1%, 3%, 5% and 10%. RESULTS: The results showed that the method of extraction of CoQ10 in a […]